Recording ECG Leads | 12 standard leads: I, II, III, aVR, aVL, aVF , V1, V2, V3, V4, V5, V6 | ||
Lead Group | Standard / Cabrera / User defined combination | ||
Recording Mode | Auto / Manual / Copy / Elapsed / Rhythm / Calibration | ||
Recording Channel | 12 / 6+1 / 3+1 ch 1-ch (lead II) / 2-chLead II,V5) / 3-ch (Lead I, II, V5) rhythm record |
||
Displaying Channel | 12 / 6 / 4 / 3 / 2 / 1 ch. | ||
Sensitivity (mm/mV) | 2.5, 5, 10, 20, [40, Auto (option)] | ||
Type | 812NH | Non-interpretive | |
812RH | 812NH + Interpretive | ||
812RSH | 812RH + Stress ECG interface | ||
Recording Speed (mm/sec) | Auto | 5,10, 12.5, 25, 50, [100 (option)] | |
Manual | 25, 50 | ||
Recording System | High resolution thermal head printer with 8 dots/mm Resolution : Vertical/ Horizotal:203/508dpi |
||
Recording paper | 216 mm x 30 m Thermal sensitive roll type A4 or Letter size Thermal sensitive Z-Folder type (option) |
||
Recording length(auto) | User selected length (5 ~ 25 sec ) | ||
ECG Data acquisition | Simultaneous 12-lead ECG | ||
Elapsed Rhythm Record | Latest 5 ~ 10 sec signal record | ||
Full Disclosure Report | User selected a lead signal and record compact rhythm for 1 min. | ||
Patient Data Input | Alphanumeric key with touch screen key pad | ||
Language | English, Spanish, Russian, Turkish, Korean | ||
Frequency Response | Unfiltered 0.05 ~ 200 Hz (-3dB) | ||
Digital filter | Baseline drift (0.05 / 0.5Hz) Muscle (25 / 35Hz) and AC (50 / 60 Hz) High frequency noise filter (75 / 100 / 150 / 200 Hz) |
||
Calibration Test (1 mV) | Frequency response and sensitivity test using internal 1 mV signal | ||
Auto Power Switch off | After 5. 10, 15 minutes inactive operation | ||
Power Requirements | AC | AC 100~240V±10 %, ~50 / 60 Hz (Fully changed 2hrs record) | |
DC | Built-in rechargeable battery ( NiMH, +19.2V, 2200mAh ) | ||
A/D Conversion | 12 bits | ||
Sampling Rate | 500 Hz | Input Unit : 8,000 Samples/s | ||
Input Impedance | Greater than 100 MΩ | ||
CMRR | Greater than 100dB | ||
Detection Parameter | Pace maker detection (Option) / Variable R-R detection / Real timeheart rate | ||
Alarm | Paper empty / Lead-off / Low battery level | ||
Performance | AAMI requirements | ||
Safety | Class I (Degree of protection against electric shock: Defibrillation-proof type CF applied parts) IEC60601-1 /IEC60601-2-25 |
||
Patient Leakage Current | Less than 10 ㎂ | ||
Digital Interface Port | 2 USB-RS232, Ethernet LAN(optional) Wireless-Biuetooth | ||
PC Connection | PC Data Management with TRISMED PC Net S/W (option) Stress ECG interface with TRISMED Stress ECG S/W (option) |
||
External printer | USB connection (Inkjet / Laser printer) | ||
Memory | Internal SD card to save up to 2500 patients data (10 sec data) External USB memory stick |
||
Display LCD | 7” Color, 800x480dots, Viewing area:152.40mm x91.44 mm | ||
Key Operation | Alphanumeric Membrane Hard Key and Touch Screen | ||
Dimension (Cardipia 800) | 332 x 308 x 103.8 mm | ||
Weight (Cardipia 800) | 3.3 Kg including battery | ||
Temperature | Operating ( 10 ~ 40 ℃) Storage (-20 ~ 60 ℃) | ||
Relative humidity | Operating ( 10 ~ 80 %) Storage (10 ~ 90 %) | ||
Atmosphere pressure | 50~ 106 kPa |
Technical Specification (Stress ECG S/W)
Lead system | 12 standard leads | ||
Recorded signal frequency range | 0.05 ~ 75 Hz | ||
ECG amplifier | Input from Type 406RSH and 812RSH | ||
A/D converter | 12bits | ||
Paper speed | 25 mm/sec | ||
Protocol | USB port for Nurytec Treadmill (VR3000TSM) Computer control treadmill speed and incline |
||
PC | Pentium Ⅳ 1GB RAM memory Hard disk with at least 40GB of free space SVGA display USB port Compatible ECG |