COMFORT COUGH

COMFORT COUGH

COMFORT COUGH II (Model: CC20, CC20P)

the most updated Mechanical In-Exsufflator (MI-E), has been developed to help the patients who cannot clear the bronchopulmonary secretions by oneself due to the various reasons.

Oscillation can be set at Inspiratory or Expiratory phase to assist in loosening and mobilizing the secretions to promote the clearance of secretions. 

 

Comfort Cough II offers Nine presets to accommodate different patient conditions or circumstances once they have been discharged from the hospital 

 

Physical

Dimensions

287x273x218mm (WxHxD)

Weight

1Set, 4.6kg (without accessories)

Device performance Spec

Parameter

Auto Mode

Manual Mode

Modes of Operation

Auto, Manual, Percussor

Preset

1 to 9

Inhale Pressure(Ip)

0 to +70cmH2O (1cmH2O Increment)

Exhale Pressure(Ep)

0 to -70cmH2O (1cmH2O Increment)

Inhalation, Exhalation, Pause Time

0.0 to 5.0 seconds
(0.1 second Increment)

N/A

Cough-Sync

On/Off

N/A

Inhale Flow rate

LOW, MID, HIGH

Oscillation

OFF/Inhale/Exhale/Both

Frequency

1 to 20Hz (1Hz Increment)
Only available if Oscillation is activated 

Amplitude

1 to 10 cmH2O (1cmH2O Increment)
Only available if Oscillation is activated

Percussor mode

Inhale Pressure

0 to +70cmH2O (1cmH2O Increment)

Frequency

10 to 780CPM (10CPM Increment)

I:E Ratio

5:1 to 1:5

Time set

Pressure set value: 0 to +40cmH2O: 29min 59sec
Pressure set value: +41 to +70cmH2O: 19min 59sec

Auto and Manual mode

For the patients who are unable to cough or clear secretions effectively due to the reduced peak cough expiratory flow. CC20 stimulates the natural cough by shifting positive pressure to negative pressure rapidly.

  • Pressure setting:
    Inhale Pressure(IP): 0 to 70cmH2O
    Exhale Pressure(EP): 0 to -70cmH2O
  • Inhale flow: Low, Medium, High

Auto and Manual mode with Oscillation

Oscillation can be set at Inspiratory or Expiratory phase to assist in loosening and mobilizing the secretions to promote the clearance of secretions. 

  • Frequency Setting: 1 to 20Hz
  • Amplitude Setting: 1 to 10cmH2O

Patient data management

Patient data are saved at SD Card and the data can be reviewed at Computer via Comfort Reader. It leads the improvement of patient care as well as clinical evaluation.

Percussor mode

With mask: To mobilize secretions toward the upper airway
With Percussion wrap: High Frequency Chest Wall Vibration Therapy 

  • Pressure setting: 0 to +70cmH2O
  • Frequency setting: 10 to 780CPM

9 Presets

Comfort Cough II offers Nine presets to accommodate different patient conditions or circumstances once they have been discharged from the hospital 

Safety Lock

To prevent unintentional or accidental touch to the keys, the control keys can be locked. Power ON/OFF and ‘START/STOP’ buttons will not be locked at anytime. 

COMFORT COUGH

About Product

  • Monitoring Peak Cough Flow and Tidal volume Peak Cough Flow and Tidal Volume are displayed after each cycle:
  • Percussor mode With mask: To mobilize secretions toward the upper airway
  • Auto and Manual mode CC20 stimulates the natural cough by shifting positive pressure to negative pressure rapidly.
Always supplied with the product

Included accessories

Join our partners' network

Get latest updates and offers

Loading......